Installation Procedure
WARNING: This page is about a different variant/trim than selected.
- Install the generator control and battery module (2) in through the trunk opening.
- Slide the generator control and battery module into position and install the vent tube (1) into the floor.
- Remove the EL-48264 battery pack lifting adapter.
- Install the generator control and battery module (3) into position and tighten the mounting bolts (1) to 22 (16 lb ft).
- Install the generator control and battery module mounting nuts (2) and tighten to 22 (16 lb ft).
- Install the generator control and battery module mounting bolts (1) and tighten to 22 (16 lb ft).
- Install the body harness connectors (1).
- Install the drive motor battery cooling air inlet duct (1). Refer to Drive Motor Battery Cooling Air Inlet Duct Replacement .
- Install the drive motor generator bracket and drive motor battery cooling blower (2). Tighten the fasteners (1) to 9 (80 lb in).
- Install the drive motor battery cooling blower outlet upper duct (1). Refer to Drive Motor Battery Cooling Air Outlet Duct Replacement (LUK) .
- Install the high voltage 3-phase cable (2) to the generator control and battery module. Tighten the nuts (1) to 9 (80 lb in).
- Install the 12V cable (3) to the generator control and battery module. Tighten the nut (4) to 9 (80 lb in).
- Install the drive motor battery cooling blower cover. Refer to Drive Motor Battery Cooling Blower Cover Replacement (With HP6) .
- Install the rear end trim finish panels. Refer to Rear End Trim Finish Panel Replacement .
- Install the rear compartment floor panel. Refer to Rear Compartment Floor Panel Trim Replacement (Without HP6) , Rear Compartment Floor Panel Trim Replacement (With HP6) .
- Install the rear compartment floor panel front trim. Refer to Rear Compartment Floor Panel Front Trim Replacement (With HP6) .
- Enable the high voltage battery. Refer to High Voltage Enabling .
- Program the generator control module, if replaced. Refer to Control Module References .
- Program the battery energy control module, if replaced. Refer to Battery Energy Control Module Programming and Setup .
NOTE:
If the length of the vent tube is too short, replace it with the vent tube on the old generator control and battery module.
CAUTION:
Refer to Fastener Caution .
NOTE:
Make sure the duct is flush against the seal for efficient generator control and battery module cooling.
NOTE:
Make sure the duct is flush against the seal for efficient generator control and battery module cooling.
NOTE:
Critical high voltage fastener. Perform second torque verification check following re-assembly.