Heating, Ventilation and Air Conditioning Control Module Scan Tool Information

HVAC Control Module Scan Tool Data Parameters

Parameter Expected Value Definition
Operating Conditions:  Engine ON
A/C Evap. Temperature Sensor Varies This displays °C (°F). This is the current temperature at the A/C evaporator temperature sensor.
A/C Head Pressure Normal The scan tool displays Normal or Out of Range. This is the state of the A/C head pressure.
A/C LED Off The scan tool displays On or Off. This is the state of the air conditioning indicator.
AC Permission Granted The scan tool displays Granted or Withheld.
A/C Request No The scan tool displays Yes or No. Yes is displayed if the air conditioning is requested.
A/C Switch Inactive The scan tool displays Active or Inactive. This is the state of the A/C switch.
Ambient Air Temperature Normal The scan tool displays Normal or Out of Range. This is the state of the ambient air temperature.
Air Inlet Dr Actual Varies This displays Counts. This is the current numeric value of the air inlet door as monitored by the HVAC module.
Air Inlet Dr Commanded Varies This displays Counts. This is the numeric value of the air inlet door as commanded by the HVAC module.
Air Inlet Motor Drive Varies The scan tool displays Stop, Ambient Air, Increase, Recirculate or Decrease. This is the state of the air inlet motor.
Auto Switch Inactive The scan tool displays Active or Inactive. This is the state of the auto switch.
Aux. Blower Motor PWM Varies This displays percent. This is the percentage of power supplied to the auxiliary blower motor.
Aux. Mode Door Actual Varies This displays Counts. This is the current numeric value of the auxiliary mode door as monitored by the HVAC module.
Aux. Mode Door Commanded Varies This displays Counts. This is the numeric value of the auxiliary mode door as commanded by the HVAC module.
Aux. Temp. Dr. Motor Command Varies This displays Counts. This is the numeric value of the auxiliary temperature door motor as commanded by the HVAC module.
Aux. Temp. Dr. Motor Position Varies This displays Counts. This is the numeric value of the auxiliary temperature door position as monitored by the HVAC module.
Battery Voltage Normal The scan tool displays Normal or Out of Range. This is the state of the system voltage.
Battery Voltage Signal Varies This displays Volts. This is the battery voltage signal supplied to the HVAC module.
Blower Motor Speed Command Varies This displays percent. This is the percentage of power supplied to the blower motor.
Blower Speed Off The scan tool displays Normal or Off. This is the state of the blower motor speed.
Coolant Temperature Varies This displays °C (°F). This is the current temperature of the engine coolant.
Engine Coolant Temp Normal The scan tool displays Normal or Out of Range. This is the state of the engine coolant temperature.
Engine Running Yes The scan tool displays Yes or No. Yes is displayed if the engine is running.
Fan Down Button Inactive The scan tool displays Active or Inactive. This is the state of the fan down switch.
Fan Up Button Inactive The scan tool displays Active or Inactive. This is the state of the fan up switch.
Front Defrost LED Off The scan tool displays On or Off. This is the state of the front defrost indicator.
Front Defrost Switch Inactive The scan tool displays Active or Inactive. This is the state of the front defrost switch.
Ign. Cycles Since last DTC Varies This displays a numeric value. This is the number of ignition cycles since the last HVAC module DTC.
Inside Air Temp. Sensor Varies This displays °C (°F). This is the current temperature of the vehicle interior.
Left Sunload Sensor Varies This displays Counts. This is an approximate value at the left sunload sensor.
Left Temp Dr Actual Varies This displays Counts. This is the current numeric value of the driver temperature door as monitored by the HVAC module.
Left Temp. Dr. Commanded Varies This displays Counts. This is the numeric value of the driver temperature door as commanded by the HVAC module.
Left Temp. Setting Varies This displays °C (°F). This is the temperature setting of the driver side area.
LH AC Duct Actual Varies This displays °C (°F). This is the current temperature of the driver side duct area.
LH AC Duct Desired Varies This displays °C (°F). This is the desired temperature of the driver side duct area.
LH Heater Actual Varies This displays °C (°F). This is the current temperature of the driver side duct area.
LH Heater Duct Desired Varies This displays °C (°F). This is the desired temperature of the driver side duct area.
Low Pressure Switch Closed The scan tool displays Open or Closed. This is the state of the low pressure switch.
Mode Door Actual Varies This displays Counts. This is the current numeric value of the mode door as monitored by the HVAC module.
Mode Down Switch Inactive The scan tool displays Active or Inactive. This is the state of the mode down switch.
Mode Dr. Motor Command Varies This displays Counts. This is the numeric value of the mode door as commanded by the HVAC module.
Mode Select Position Off The scan tool displays Off, Auto, Defrost, Heater, Htr./Def., Bi-Level or Panel. This is the current position of the HVAC mode select.
Mode Switch Pos. Varies The scan tool displays Invalid, Auto, Panel, Bi-Level, Heater, Htr./Def. or Defrost. This is the state of the HVAC mode switch.
Mode Up Switch Inactive The scan tool displays Active or Inactive. This is the state of the mode up switch.
On/Off Switch Inactive The scan tool displays Active or Inactive. This is the state of the on/off switch.
Outside Air Temp. Filtered Varies This displays °C (°F). This is the filtered value of the outside air temperature.
Outside Air Temp. Raw Varies This displays °C (°F). This is the raw value of the outside air temperature.
Rear Defrost LED Off The scan tool displays On or Off. This is the state of the rear defrost indicator.
Rear Defrost State Off The scan tool displays On or Off. This is the state of the rear defrost system.
Rear Defrost Switch Inactive The scan tool displays Active or Inactive. This is the state of the rear defrost switch.
Recirculation LED Off The scan tool displays On or Off. This is the state of the recirculation indicator.
Recirculation Switch Inactive The scan tool displays On or Off. This is the state of the recirculation switch.
RH AC Duct Actual Varies This displays °C (°F). This is the current temperature of the passenger side duct area.
RH AC Duct Desired Varies This displays °C (°F). This is the desired temperature of the passenger side duct area.
RH Heater Actual Varies This displays °C (°F). This is the current temperature of the passenger side duct area.
RH Heater Duct Desired Varies This displays °C (°F). This is the desired temperature of the passenger side duct area.
Right Sunload Sensor Varies This displays Counts. This is an approximate value at the right sunload sensor.
Right Temp Dr Actual Varies This displays Counts. This is the current numeric value of the passenger temperature door as monitored by the HVAC module.
Right Temp. Dr. Commanded Varies This displays Counts. This is the numeric value of the passenger mode door as commanded by the HVAC module.
Right Temp. Setting Varies This displays °C (°F). This is the temperature setting of the passenger side area.
HVAC Control Module Scan Tool Output Controls

Scan Tool Output Control Description
A/C Request This command allows you to turn the A/C Relay On and Off. When the A/C Relay is commanded On, the A/C compressor clutch should be engaged.
Afterblow Option The rear HVAC/RSA module will illuminate all indicators and display segments on the module display.
Air Inlet Door When Outside is selected, the HVAC control module commands the recirculation actuator toward the outside air position. When Recirc is selected, the HVAC control module commands the recirculation actuator toward the recirculation position. This is shown through a command of On and Off.
All Status LEDs All HVAC status LEDs illuminate when ON is selected and turn off when OFF is selected.
Auxiliary Air Temp. Door When Cold is selected, the HVAC control module commands the rear air temperature actuator to the full cold position. When Hot is selected, the HVAC control module commands the rear air temperature actuator to the full hot position.
Auxiliary Blower Motor When ON is selected, the HVAC control module commands the blower motor relay ON and an increase or decrease of air. When OFF is selected, the HVAC control module commands the blower motor relay OFF.
Auxiliary Mode Door When ON is selected, the HVAC control module commands the blower motor relay ON and an increase or decrease of air. When OFF is selected, the HVAC control module commands the blower motor relay OFF.
Blower Motor When ON is selected, the HVAC control module commands the blower motor relay ON and a command to increase or decrease air. When OFF is selected, the HVAC control module commands the blower motor relay OFF.
Instant OAT Update This command updates the outside air temperature.
Left Temp. Door Position This commands the right temperature door position from Cold to Hot.
Mode Door Position When A/C is selected, the HVAC control module commands the mode actuator to the panel position. When Defrost is selected, the HVAC control module commands the actuator to the defrost position.
Rear Defog Request The BCM must receive a Rear Defog request from the HVAC control module in order to enable the output control. The BCM de-energizes the Rear Defog relay located in the I/P BEC when OFF is selected. The relay remains de-energized until ON is selected.
Recalibrate All Motors When ON is selected, all air temp and mode actuators have the capability to perform a recalibration.
Right Temp. Door Position This commands the right temperature door position from Cold to Hot.