Circuit/System Testing
NOTE:
You must perform the Circuit/System Verification before proceeding with Circuit/System Testing.
- Ignition OFF.
- Test for less than 2 Ω between the G13 Generator housing and battery negative terminal.
- If 2 Ω or greater
Repair the open/high resistance in the circuit.
- Go to next step: If less than 2 Ω
- If 2 Ω or greater
- Ignition OFF, disconnect the X2 harness connector at the G13 Generator.
- Verify a test lamp illuminates between the G13 Generator B+ circuit terminal 1 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF, remove the test lamp.
- Test for less than 2 Ω in the B+ circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF, remove the test lamp.
- Test for infinite resistance between the B+ circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, test or replace the G13 Generator.
- Go to next step: If the test lamp illuminates
- Ignition OFF, disconnect the X1 harness connector at the G13 Generator.
- Verify a test lamp illuminates between the G13 Generator B+ circuit terminal 2 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF, remove the test lamp.
- Test for less than 2 Ω in the B+ circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF, remove the test lamp.
- Test for infinite resistance between the B+ circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, test or replace the G13 Generator.
- Go to next step: If the test lamp illuminates
- Disconnect the X1 harness connector at the X50A Fuse Block - Underhood.
- Test for less than 1 V between the control circuit terminal 8 at the X50A Fuse Block - Underhood and ground.
- If 1 V or greater
Repair the short to voltage on the circuit.
- Go to next step: If less than 1 V
- If 1 V or greater
- Test for infinite resistance between the control circuit terminal 8 at the X50A Fuse Block - Underhood and ground.
- If less than infinite resistance
Repair the short to ground on the circuit.
- Go to next step: If infinite resistance
- If less than infinite resistance
- Test for less than 2 Ω in the control circuit end to end.
- If 2 Ω or greater
Repair the open/high resistance in the circuit.
- Go to next step: If less than 2 Ω
- If 2 Ω or greater
- Test or replace the G13 Generator