Installation Procedure
- Install the APM module (4) into the retainer clip (1) and position the APM module against the back stop bracket (2).
- Install the APM module retainer tray brackets in the "UP" position and tighten the fasteners (1) to 22 N.m (16 lb ft).
- Install the drive motor generator control module cooling outlet hose (Straight Hose) at the rear of the APM module. Refer to Drive Motor Generator Control Module Cooling Outlet Hose Replacement (Straight Hose) .
- Connect the APM module cable connector (1) to the right side of the APM module (2).
- Install the generator control module coolant hose at the front of the APM module. Refer to Generator Control Module Coolant Hose Replacement (PE From APM TO TPIM) .
- Connect the engine harness connector (1) to the front right side of the APM module (2).
- Install the battery positive cable (3) to the APM module stud (4) and tighten the fastener (2) to 22 N.m (16 lb ft).
- Install the protective boot (1).
- Install the APM module ground cable (1) to the APM module and tighten the fastener (2) to 9 N.m (80 lb in).
- Install the drive motor generator power inverter module. Refer to Drive Motor Power Inverter Module Replacement .
- Install the high voltage battery disconnect control module. Refer to High Voltage Battery Disconnect Control Module Replacement (with quick charge) High Voltage Battery Disconnect Control Module Replacement (without quick charge)
- Install the high voltage disconnect circuit cover. Refer to High Voltage Disconnect Circuit Connector Cover Replacement .
- Enable the high voltage system. Refer to High Voltage Enabling .
CAUTION:
Refer to Fastener Caution .