Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the generator.
- Ignition ON, test for less than 1 volt between the generator turn on signal circuit and ground.
- If greater than the specified value, test the generator turn on signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Engine Running, test for greater than 3.5 volts between the generator turn on signal and ground.
- If less than the specified value, test the generator turn on signal circuit for a short to ground, an open/ high resistance. If the circuit tests normal, replace the ECM.
- If the circuit tests normal, test or replace the generator.