Installation Procedure

  1. GM4529660Courtesy of GENERAL MOTORS COMPANY

    Accessory DC Power Control Module (1) - Install

  2. GM4529659Courtesy of GENERAL MOTORS COMPANY

    Engine Wiring Harness Bracket (1) - Install [2x]

  3. GM4529658Courtesy of GENERAL MOTORS COMPANY
    CAUTION:

    Refer to Fastener Caution .

    Accessory DC Power Control Module Bolt (1) - Install [2x] 22N.m (16 lb ft)

  4. Accessory DC Power Control Module Stud (2) - Install 22N.m (16 lb ft)
  5. GM4545651Courtesy of GENERAL MOTORS COMPANY

    Battery Negative Cable Extension Cable & Battery Positive Cable - Install

  6. Battery Positive Cable and Nut (2) - Install and tighten 15N.m (11 lb ft)
  7. Battery Positive Cable Protector (3) - Install
  8. Battery Negative Cable Extension Cable Fastener (1) - Install and tighten 15N.m (11 lb ft)
  9. GM4529656Courtesy of GENERAL MOTORS COMPANY

    Electric Differential Drive Motor Power Inverter Module Cooling Hose (3) - Install the Hose and Engage the Clamp (1)

  10. Drive Motor Generator Control Module Cooling Outlet Hose (2) - Install the Hose and Engage the Clamp (1)
  11. GM4529655Courtesy of GENERAL MOTORS COMPANY

    Low Voltage connection connector (1) - Connect @ Accessory DC Power Control Module

  12. GM4529631Courtesy of GENERAL MOTORS COMPANY

    Auxiliary Power Module Connector (1) - Connect

  13. Fig 1: Identifying DC Power Control Module Components
    GM4529630Courtesy of GENERAL MOTORS COMPANY

    Accessory DC Power Control Module High Voltage Connector Protector (5) - Install

  14. Accessory DC Power Control Module High Voltage Connector Protector Bolt (4) - Install 9N.m (80 lb in)
  15. Accessory DC Power Control Module High Voltage Connector Protector Bolt (3) - Install 22N.m (16 lb ft)
  16. Accessory DC Power Control Module High Voltage Connector Protector Nut (2) - Install 9N.m (80 lb in)
  17. Install the battery to battery positive cable retainers.
  18. Fill the drive motor generator power inverter module cooling system. Drive Motor Generator Power Inverter Module Cooling System Draining and Filling
  19. Enable the high voltage system. High Voltage Enabling