Installation Procedure
Accessory DC Power Control Module (1) - Install
Engine Wiring Harness Bracket (1) - Install [2x]
- CAUTION:
Refer to Fastener Caution .
Accessory DC Power Control Module Bolt (1) - Install [2x] 22N.m (16 lb ft)
- Accessory DC Power Control Module Stud (2) - Install 22N.m (16 lb ft)
Battery Negative Cable Extension Cable & Battery Positive Cable - Install
- Battery Positive Cable and Nut (2) - Install and tighten 15N.m (11 lb ft)
- Battery Positive Cable Protector (3) - Install
- Battery Negative Cable Extension Cable Fastener (1) - Install and tighten 15N.m (11 lb ft)
Electric Differential Drive Motor Power Inverter Module Cooling Hose (3) - Install the Hose and Engage the Clamp (1)
- Drive Motor Generator Control Module Cooling Outlet Hose (2) - Install the Hose and Engage the Clamp (1)
Low Voltage connection connector (1) - Connect @ Accessory DC Power Control Module
Auxiliary Power Module Connector (1) - Connect
-
Accessory DC Power Control Module High Voltage Connector Protector (5) - Install
- Accessory DC Power Control Module High Voltage Connector Protector Bolt (4) - Install 9N.m (80 lb in)
- Accessory DC Power Control Module High Voltage Connector Protector Bolt (3) - Install 22N.m (16 lb ft)
- Accessory DC Power Control Module High Voltage Connector Protector Nut (2) - Install 9N.m (80 lb in)
- Install the battery to battery positive cable retainers.
- Fill the drive motor generator power inverter module cooling system. Drive Motor Generator Power Inverter Module Cooling System Draining and Filling
- Enable the high voltage system. High Voltage Enabling