Ch2 - Checking Battery Temp Sensor Calibration
- With tester connected to diagnostic connector, put system in Engine Running Test "61". If display on tester reads between .2-3 volts, go to next step. If display on tester is not reading between .2-3 volts, replace SMEC for a bad logic board.
- Put system in Engine Running Test "67". If display on tester reads between 13-15 volts, check battery and also check for battery drain down condition. If display on tester is not reading between 13-15 volts, check alternator.