Structural Collar/Cover: Installation

WARNING: This page is about a different variant/trim than selected.
CAUTION: The collar must be tighten using this service procedure, as damage to collar and/or oil pan may occur.
  1. Install structural collar (Figure) using the following tightening sequence:
    1. Install the vertical  collar to oil pan bolts. Torque bolts initially to 1.1 N.m (10 in. lbs.).
    2. Install the horizontal  collar to transmission bolts and torque to 55 N.m (40 ft. lbs.).
    3. Starting with the center vertical bolts and working outward, final torque bolts to 55 N.m (40 ft. lbs.).
  2. Lower vehicle.