Power Window Switch: Testing and Inspection

Master Window Switch Connector:




Master Window Switch Test:




Passenger Window Switch:




Passenger Window Switch Test:




For switch testing, remove the switch. (Refer to ELECTRICAL/POWER WINDOWS/POWER WINDOW SWITCH - REMOVAL ). Using an ohmmeter, refer to Window Switch Continuity Charts to determine if continuity is correct and. If the results are not obtained, replace the switch.

The master window switch has an Auto-Down feature. Actuation of the master switch to the second down position will move the drivers side window completely down. The electronic switch will automatically disconnect the motor approximately 1 second after the window bottoms out. Failure of the electronic switch to detect stall current, will cause the switch to disconnect after approximately 13 seconds. The auto down function can be canceled by any movement of that switch.