Vacuum Control Flap Switchover Valve: Service and Repair




RECIRC AIR SWITCHOVER VALVE

REMOVAL




1. Remove the glove compartment.
2. Disconnect the vacuum lines (1) from the recirculation switchover valve.
3. Disconnect the recirculation switchover valve harness connector from the recirculation switchover valve.
4. Remove the recirculation switchover valve.

INSTALLATION




1. Install the recirculation switchover valve.
2. Connect the recirculation switchover valve harness connector to the recirculation switchover valve.
3. Connect the vacuum lines (1) to the recirculation switchover valve.
4. Install the glove compartment.