Controller Antilock Brake: Installation
WARNING: This page is about a different variant/trim than selected.
- Install screws to secure the CAB to the HCU half of the ICU. Tighten the mounting screws to 2 N.m (17 in. lbs.) torque.
- Remount the ICU mounting bracket to the lower radiator support. Tighten the mounting bolts to 28 N.m (21 ft. lbs.) torque.
- Reconnect the 24-way electrical and the pump/ motor connector.
- Lower vehicle.
- Connect negative battery cable.
- Connect a DRBIII® to the vehicle and initialize the system.