LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chrysler >> 2004 >> Sebring Convertible V6-2.7L VIN R >> Repair and Diagnosis >> Heating and Air Conditioning >> Multi-Function Thermal Sensor / Switch >> Testing and Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Multi-Function Thermal Sensor / Switch: Testing and Inspection

THERMAL LIMITER SWITCH
1. Unplug Thermal Limiter connector.
2. With an ohmmeter, check for continuity between the two terminals. If no continuity is present replace compressor.
3. The Thermal Limiter is calibrated to open and close at:
- Open circuit (no continuity) Temperature: 122 -128° C (252 - 262° F)
- Close circuit (continuity) Temperature: 106 -116° C (225 - 235° F)

NOTE: The thermal limiter switch is not serviceable. If the switch fails, the compressor must be replaced.