When Monitored and Set Condition

  1. When Monitored: Engine Running and Heater duty cycle greater than 0%.
  2. Set Condition: O2 Heater Temperature does not reach 575°C (959°F) within 90 second during monitoring conditions. Two Trip Fault.
Possible Causes 
O2 HEATER ELEMENT
FUSED ENGINE CONTROL RELAY OUTPUT CIRCUIT OPEN
O2 HEATER CONTROL CIRCUIT OPEN
POWERTRAIN CONTROL MODULE

For a complete Powertrain Control Module Circuit Diagram, (Refer to ENGINE - SCHEMATICS AND DIAGRAMS) .