Possible Causes
| Possible Causes |
|---|
| (Internal) FUSED B+ CIRCUIT OPEN |
| (T16) TRANSMISSION CONTROL RELAY OUTPUT CIRCUIT OPEN |
| (T15) TRANSMISSION CONTROL RELAY CONTROL CIRCUIT OPEN |
| (Z901) TRANSMISSION CONTROL RELAY GROUND CIRCUIT OPEN |
| (T15) TRANSMISSION CONTROL RELAY CONTROL CIRCUIT SHORT TO GROUND |
| (T16) TRANSMISSION CONTROL RELAY OUTPUT CIRCUIT SHORT TO GROUND |
| TRANSMISSION CONTROL RELAY |
| TRANSMISSION SOLENOID/PRESSURE SWITCH ASSEMBLY |
| POWERTRAIN CONTROL MODULE |