Fuel Level Sending Unit
- Install fuel level sending card to module.
- Connect electrical connector for fuel level sending card.
- Install module top to module.
- Install module into the tank with the level unit towards rear of tank.
- Install a new seal onto the tank, making sure seal is properly seated in tank groove.
- Install module lock ring.NOTE: Use a brass punch to Install the 1/4 turn lock ring. Make sure all 5 tabs are properly seated.
- Connect vapor line and electrical connector.
- Install fuel tank, see INSTALLATION .
- Connect negative battery cable.
- Fill fuel tank. Use the scan tool to pressurize the fuel system. Check for leaks.