MANUFACTURER
ENGINE
NOMINAL RATING
MINIMUM OUTPUT (AMPS) (@ SPECIFIED TEST CONDITIONS)
MITSUBISHI ELECTRIC
2.0L, 2.4L
120A
70A
DENSO
3.6L
140A
90A
TEST CONDITIONS
1. Engine RPM : 2500 RPM (ENGINE HOT)
2. Voltage Output : 13.0 - 16.0 V