Jumper Harness
- Connect the ORC jumper harness (2) to the body harness (3).
- Connect the ORC jumper harness connector (4) to the ORC (1).
- Install the center console. Refer to HOUSING, SHIFTER, INSTALLATION .
- Do not reconnect the negative cable to the battery at this time. The Supplemental Restraint System (SRS) Verification Test procedure should be performed following service of any SRS component.
Refer to STANDARD PROCEDURE .