LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Dodge and Ram >> 1989 >> Lancer Base, 2.2 D, Standard >> Repair and Diagnosis >> Engine Performance >> System >> 2.5L Turbo Tests W/Codes >> DTC Identification >> Fault Code Descriptions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Fault Code Descriptions

FAULT CODE DESCRIPTIONS

Code Display on DRB-0II Fault Condition:
11 IGN REFERENCE SIGNAL No Distributor Reference Signal Picked Up During Cranking.
12 NUMBER OF KEY-ONS SINCE LAST FAULT OR SINCE FAULT WERE ERASED. Direct Battery Input To SMEC Was Disconnected Within 50- 100 Ignition Key-Ons.
13  MAP PNEUMATIC SIGNAL No Difference In MAP Sensor Signal Detected.
13  MAP PNEUMATIC CHANGE No Difference Detected Between MAP Reading And Stored Barometric Pressure Reading.
14  MAP VOLTAGE TOO LOW MAP Sensor Input Less Than Minimum Acceptable Voltage.
14  MAP VOLTAGE TOO HIGH MAP Sensor Input More Than Maximum Acceptable Voltage.
15  VEHICLE SPEED SIGNAL No Distance Sensor Signal Detected W/Road Load Conditions.
16 BATTERY INPUT SENSE Battery Voltage Sense Input Not Detected With Engine Running.
17 LOW ENGINE TEMP Coolant Temperature Stays Below Normal Operating Temperature During Vehicle Operation.
21  OXYGEN SENSOR SIGNAL No Rich Or Lean Signal Is Detected From O2 Sensor Input.
22  COOLANT VOLTAGE LOW Coolant Temp. Sensor Input Below Minimum Acceptable Voltage.
22  COOLANT VOLTAGE HIGH Coolant Temp. Sensor Input Above Maximum Acceptable Voltage.
24  TPS VOLTAGE LOW TPS Sensor Output Less Than Minimum Acceptable Voltage.
24  TPS VOLTAGE HIGH TPS Sensor Output More Than Maximum Acceptable Voltage.
25  AIS MOTOR CIRCUITS Shorted Condition Detected In One Or More AIS Control Circuits.
26 INJ 1 PEAK CURRENT OR INJ 2 PEAK CURRENT High Resistance Detected In INJ 1 Injector Bank Circuit. High Resistance Detected In INJ 2 Injector Bank Circuit.
27 INJ 1 CONTROL CIRCUIT OR INJ 2 CONTROL CIRCUIT INJ 1 And INJ 2 Injector Banks Output Driver Stages Do Not Respond Correctly To SMEC Control Signals.
31  PURGE SOLENOID CKT Open Or Shorted Condition Is Detected In Purge Solenoid Ckt.
32  EGR SOLENOID CIRCUIT Open Or Short Is Detected In EGR Solenoid Circuit (CA Only).
32  EGR SYSTEM FAILURE SMEC Did Not Detect Required Air/Fuel Change During Diagnostic Test (CA Only).
33  A/C CLUTCH RELAY CKT Open/Shorted Condition Detected In A/C Clutch Relay Circuit.
34 S/C SERVO SOLENOIDS Open/Shorted Condition Detected In Speed Control Vacuum Or Vent Solenoid Circuits.
35  RADIATOR FAN RELAY Open/Shorted Condition Detected In Radiator Fan Relay Circuit.
36  WASTEGATE SOLENOID Open/Shorted Condition Dected In Turbocharger Wastegate Control Solenoid Circuit.
41 CHARGING SYSTEM CKT Output Driver Stage Does No Respond Correctly To Voltage Regulator Control Signal.
42 ASD RELAY CIRCUIT OR Z1 VOLTAGE SENSE Open Or Shorted Condition Detected In Asd Relay Circuit No Battery Voltage Sensed When Asd Relay Is Energized
43 IGNITION CONTROL CIRCUIT Output Driver Stage For Ignition Coil Does Not Respond Properly To Dwell Control Signal.
44  FJ2 VOLTAGE SENSE No FJ2 Voltage Present At Logic Board During SMEC Operation.
45  BOOST LIMIT EXCEEDED MAP Reading Above Overboost Limit Detected During Engine Operation.
46 BATTERY VOLTAGE HIGH Battery Voltage Sense Input More Than Target Charging Voltage During Engine Operation.
47 BATTERY VOLTAGE LOW Battery Voltage Sense Input Less Than Target Charging Voltage During Engine Operation.
51 LEAN F/A CONDITION Oxygen Sensor Input Indicates Lean Air/Fuel Ratio During Engine Operation.
52 RICH F/A CONDITION Oxygen Sensor Input Indicates Rich Air/Fuel Ratio During Engine Operation.
53 INTERNAL SELF-TEST SMEC Detects Internal Failure.
54 SYNC PICK-UP SIGNAL Fuel Synchronization Signal Not Detected During Engine Rotation.
55 " Completion Of Fault Code Display By Check Engine Light.
61  BARO READ SOLENOID Open/Shorted Condition Dected In Baro Read Solenoid Circuit.
62  EMR MILEAGE ACCUM Attempt Is Unsuccessful To Update EMR Mileage In SMEC EEPROM (Trucks Only).
63 EEPROM WRITE DENIED Attempt Is Unsuccessful To Write To An EEPROM Location By SMEC.
N/A FAULT CODE ERROR DRB-II Does Not Recognize Fault Identification.