Automatic Stop
- Connect 12 volts to one terminal and ground other terminal. Disconnect jumper wires during operation to stop motor. See AUTOMATIC STOP TERMINAL NUMBERS
for terminals and model application.
- Using a jumper wire, connect the 2 terminals together. Connect 12 volts to other terminal and ground wiper motor bracket. Make sure motor runs, then stops. See Figure
. Also, refer to JUMPER WIRE/BATTERY POSITIVE TERMINAL NUMBERS (FRONT WIPERS)
.
AUTOMATIC STOP TERMINAL NUMBERS
| Model |
Ground Terminal No. |
Voltage Terminal No. |
| Colt, Colt 200 & Summit |
|
|
| Colt Vista |
1 |
4 |
| Colt Wagon, Ram-50 |
1 |
3 |
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA. JUMPER WIRE/BATTERY POSITIVE TERMINAL NUMBERS (FRONT WIPERS)
| Model |
Jumper Terminal No. |
Voltage Terminal No. |
| Colt, Colt 200 & Summit |
|
|
| Colt Vista |
1 & 3 |
4 |
| Colt Wagon, Ram-50 |
1 & 4 |
3 |