Rectifier Testing
Using an ohmmeter, check for continuity between positive diode lead and heat sink on positive diode side. Continuity should exist in one direction only, from diode lead to heat sink. Repeat test for each diode. If continuity exists in both directions, replace rectifier assembly. Repeat test for negative diodes.