Stator Test
- Scribe generator housing for reassembly reference. Remove generator through-bolts and separate generator housings. Using ohmmeter, check for continuity between coil and core. No continuity should exist.
- If continuity exists, replace stator assembly. Check for continuity between stator coil leads. Continuity should exist. If no continuity exits, replace stator assembly.