Pinpoint Test Pc: Run The Diagnostic Tool Data Link Test
Test Step
PC1 DIAGNOSTIC TOOL DATA LINK TEST
- Carry out the diagnostic tool data link test.
- Is system passed obtained?
Result / Action to Take
Yes
RETURN to the Symptom Chart for the module in question.
No
If ISO circuit faults; all electronic control units no response/not equipped, Go To PINPOINT TEST P: NO INTERNATIONAL STANDARDS ORGANIZATION (ISO) 9141 NETWORK COMMUNICATION .
If UBP circuit faults; all electronic control units no response/not equipped, Go To PINPOINT TEST R: NO UNIVERSAL ASYNCHRONOUS RECEIVER-TRANSMITTER (UART) - BASED PROTOCOL (UBP) NETWORK COMMUNICATION .
If SCP+ circuit faults; all electronic control units no response/not equipped, Go To PINPOINT TEST Q: NO STANDARD CORPORATE PROTOCOL (SCP) NETWORK COMMUNICATION .
If SCP- circuit faults; all electronic control units no response/not equipped, Go To PINPOINT TEST Q: NO STANDARD CORPORATE PROTOCOL (SCP) NETWORK COMMUNICATION .
If no response from the diagnostic tool, Go To PINPOINT TEST S: NO MODULE/NETWORK COMMUNICATION - NO POWER TO THE DIAGNOSTIC TOOL .
If ISO or SCP circuit faults; all electronic control units no response/not equipped, REFER to SYMPTOM CHART .
If the module in question is no response on SCP+, REFER to SYMPTOM CHART .
If the module in question is no response on SCP-, REFER to SYMPTOM CHART .
If the module in question is no response/not equipped, REFER to SYMPTOM CHART .