General Procedures: Fill
- Fill the reservoir.
- Use Motorcraft MERCON® Multi-Purpose ATF XT-2-QDX or MERCON® equivalent.
- To prevent the engine from starting, remove the fuel pump relay from the battery junction box.
- Raise the front wheels off the floor. For additional information, refer to JACKING & HOISTING .
- Turn the steering wheel from stop-to-stop while cranking the engine.
- Lower the vehicle.
- Fill the reservoir.
- Use Motorcraft MERCON® Multi-Purpose ATF XT-2-QDX or MERCON® equivalent.
- Install the fuel pump relay.
- Clear the diagnostic trouble codes (DTCs). For additional information, refer to CLEARING CODES .
WARNING:
Do not mix oil types. Any mixture or any unapproved oil can lead to seal deterioration and leaks. A leak can ultimately cause loss of fluid, which can result in a loss of power steering assist.
CAUTION:
Do not crank the engine for more than 15 seconds at a time. Allow the starter to cool for 1 minute before cranking again. Premature starter failure can occur.
CAUTION:
Do not hold the steering wheel against the stops for more than three to five seconds at a time. Damage to the power steering pump can occur.
CAUTION:
Do not overfill the reservoir.