Dual-Zone EATC: Notes
The HVAC module analyzes input from the following major sources:
- Temperature, airflow direction, blower, A/C and RECIRC selection (made by the vehicle occupants)
- In-vehicle temperature/humidity sensor
- AAT sensor
- Autolamp/sunload sensor
- Vehicle speed
- ECT sensor or CHT sensor
Using these inputs, the dual-zone HVAC module determines the correct conditions for the following outputs:
- A/C compressor operation
- Blower motor speed
- RH and LH temperature blend door positions
- Defrost/panel/floor mode door position
- Air inlet mode door position