GENERAL SPECIFICATIONS

Item Specification
1.6L GTDI - 150A (base) 
Generator pulley ratio 2.49:1
Rating 90 amps at 700 rpm (min) to 155 amps at 2400 rpm (max)
Voltage regulator type Electronic internal with generator
1.6L GTDI - 175A (optional) 
Generator pulley ratio 2.49:1
Rating 120 amps at 700 rpm (min) to 180 amps at 2400 rpm (max)
Voltage regulator type Electronic internal with generator
2.0L GTDI - 150A (base) 
Generator pulley ratio 2.79:1
Rating 90 amps at 650 rpm (min) to 160 amps at 2200 rpm (max)
Voltage regulator type Electronic internal with generator
2.0L GTDI - 175A (optional) 
Generator pulley ratio 2.47:1
Rating 120 amps at 700 rpm (min) to 180 amps at 2400 rpm (max)
Voltage regulator type Electronic internal with generator
2.5L - 150A (base) 
Generator pulley ratio 2.79:1
Rating 90 amps at 650 rpm (min) to 160 amps at 2200 rpm (max)
Voltage regulator type Electronic internal with generator
2.5L - 175A (optional) 
Generator pulley ratio 2.47:1
Rating 120 amps at 700 rpm (min) to 180 amps at 2400 rpm (max)