LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2014 >> Focus ST >> Repair and Diagnosis >> Engine Performance >> Mode 6 >> Mode 6 - 2014 Ford - Except Diesel >> Comprehensive Component Monitor - Transmission
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Comprehensive Component Monitor - Transmission

General 

The MIL is illuminated for all emissions related electrical component malfunctions. For malfunctions attributable to a mechanical component (such as a clutch, gear, band, valve, etc.), some transmissions are capable of not commanding the mechanically failed component and providing the remaining maximum functionality (functionality is reassessed on each power up)- in such case a non-MIL Diagnostic Trouble Code (DTC) will be stored and, if so equipped, a Transmission Control Indicator Light (TCIL) will flash.

Transmission Inputs 

TRANSMISSION RANGE SENSOR CHECK OPERATION

DTCs P0705 invalid pattern for digital TRS
P0706 Out of range signal frequency for PWM TRS
P0707 Signal out of range low for PWM TRS
P0708 Open circuit for digital TRS or signal out of range high for PWM TRS
Monitor Execution Continuous
Monitor Sequence None
Sensors OK  
Monitoring Duration Up to 30 seconds for pattern recognition, 5 seconds for analog faults
TYPICAL TRS CHECK ENTRY CONDITIONS

Auto Transmission Entry Conditions  Minimum  Maximum 
Gear selector position each position for up to 30 seconds 480 seconds
TYPICAL TRS MALFUNCTION THRESHOLDS

Digital TRS:  Invalid pattern from 3 or 5 digital inputs and/or 1 analog circuit open for 5 seconds
4-bit digital TRS:  Invalid pattern for 200 ms
Analog TRS:  Voltage > 4.8 volts or < 0.2 volts for 5 seconds
Dual analog TRS:  Voltage > 4.84 volts or < 0.127 volts for 200 ms or
Sum of both inputs is outside the range of 5.0 volts +/- 0.29 volts for 200 ms
PWM TRS:  Frequency > 175 Hz or < 100 Hz,
Duty Cycle > 90% or < 10%

Most vehicle applications no longer have a standalone vehicle speed sensor input. The PCM sometimes obtains vehicle speed information from another module on the vehicle, i.e. ABS module. In most cases, however, vehicle speed is calculated in the PCM by using the transmission output shaft speed sensor signal and applying a conversion factor for axle ratio and tire programmed into the Vehicle ID block. A Vehicle Speed Output pin on the PCM provides the rest of the vehicle with the standard 8, 000 pulses/mile signal.

NOTE:

If the Vehicle ID block has not been programmed or has been programmed with an out-of-range (uncertified) tire/axle ratio, a P1639 DTC will be stored and the MIL will be illuminated immediately.

VEHICLE SPEED SENSOR FUNCTIONAL CHECK OPERATION

DTCs P0500 - VSS Circuit
Monitor Execution Continuous
Monitor Sequence None
Sensors OK  
Monitoring Duration 30 seconds
TYPICAL VSS FUNCTIONAL CHECK ENTRY CONDITIONS

Auto Transmission Entry Conditions  Minimum  Maximum 
Gear selector position drive  
Engine rpm (above converter stall speed) OR 3000 rpm  
Turbine shaft rpm (if available) OR 1500 rpm  
Output shaft rpm 650 rpm  
Vehicle speed (if available) 15 mph  
Manual Transmission Entry Conditions  Minimum  Maximum 
Engine load 50%  
Engine rpm 2400 rpm  
TYPICAL VSS FUNCTIONAL CHECK MALFUNCTION THRESHOLDS

Vehicle is inferred to be moving with positive driving torque and VSS is < 1 - 5 mph for 5 seconds
OUTPUT SHAFT SPEED SENSOR FUNCTIONAL CHECK OPERATION

DTCs P0720 - OSS circuit
P0721 - OSS range/performance -F-21, 6HP26
P0722 - OSS no signal
P0723 - OSS intermittent/erratic - 6HP26
Monitor Execution Continuous
Monitor Sequence None
Sensors OK TSS, Wheel Speed
Monitoring Duration 30 seconds
TYPICAL OSS FUNCTIONAL CHECK ENTRY CONDITIONS

Auto Transmission Entry Conditions  Minimum  Maximum 
Gear selector position drive  
Engine rpm (above converter stall speed) OR 3000 rpm  
Primary Pulley Speed (CFT30) OR 400 rpm  
Turbine shaft rpm (if available) OR 1500 rpm  
Output shaft rpm 300 - 650 rpm  
Vehicle Speed (if available) 12.5 - 15 mph  
TYPICAL OSS FUNCTIONAL CHECK MALFUNCTION THRESHOLDS

Circuit/no signal - vehicle is inferred to be moving with positive driving torque and OSS < 100 to 200 rpm for 5 to 30 seconds
6HP26 Circuit/no signal: open or short circuit for > 0.6 seconds
6HP Range/Performance: > 200 rpm difference between OSS and wheel speed and > 250 rpm difference between OSS and input shaft speed
F21 Range/Performance: TSS, ABS wheel speed and engine rpm correlate properly, but OSS error is greater than 15% for 10 seconds
CFT30 Range/Performance: ABS wheel speed indicates a 6.24 mph difference with OSS calculated wheel speed
6HP26 Intermittent/Erratic: > -1000 rpm instantaneous change with locked torque converter clutch
CFT30 Intermittent/Erratic: > 6000 rpm/sec change
INTERMEDIATE SHAFT SPEED SENSOR FUNCTIONAL CHECK OPERATION

DTCs P0791 - ISS circuit
Monitor Execution Continuous
Monitor Sequence None
Sensors OK  
Monitoring Duration 30 seconds
TYPICAL ISS FUNCTIONAL CHECK ENTRY CONDITIONS

Auto Transmission Entry Conditions  Minimum  Maximum 
Gear selector position drive  
Engine rpm (above converter stall speed) OR 3000 rpm  
Turbine shaft rpm (if available) OR 1500 rpm  
Output shaft rpm 650 rpm  
Vehicle speed (if available) 15 mph  
TYPICAL ISS FUNCTIONAL CHECK MALFUNCTION THRESHOLDS

Vehicle is inferred to be moving with positive driving torque and ISS < 250 rpm for 5 seconds
TURBINE SHAFT SPEED SENSOR FUNCTIONAL CHECK OPERATION

DTCs P0715 - TSS circuit/ no signal
P0718 - TSS erratic signal
Monitor Execution Continuous
Monitor Sequence None
Sensors OK OSS, Wheel Speed
Monitoring Duration 30 seconds
TYPICAL TSS FUNCTIONAL CHECK MALFUNCTION THRESHOLDS

Circuit/no signal - vehicle is inferred to be moving with positive driving torque and TSS < 200 rpm for 5 - 30 seconds
Erratic signal - observe 200 turbine speed spikes > 400 rpm with no more than 1.5 seconds between spikes
TRANSMISSION FLUID TEMPERATURE SENSOR FUNCTIONAL CHECK OPERATION

DTCs P0711 - in range failure
P0712 - short to ground
P0713 - open circuit
Monitor Execution Continuous
Monitor Sequence None
Sensors OK ECT substituted if TFT has malfunction
TFT inferred from pressure solenoid on CFT30
Monitoring Duration 5 seconds for electrical, 600 seconds for functional check
TYPICAL TFT STUCK LOW/HIGH CHECK ENTRY CONDITIONS

Auto Transmission Entry Conditions  Minimum  Maximum 
Engine Coolant Temp (hot or cold, not midrange) > 100 °F < 20 °F
Time in Run Mode 500 - 600 seconds  
Time in gear, Vehicle moving, Positive torque 150 seconds  
Vehicle Speed 15 mph  
Time with engine off (cold start) OR 420 min  
Engine Coolant Temp AND Trans Fluid Temp (inferred cold start)   122 °F
TYPICAL TFT MALFUNCTION THRESHOLDS

Opens/shorts:  TFT voltage <0.05 or > 4.6 volts for 5 - 12 seconds
TFT Stuck low/high, i.e. TFT stuck at high temperature or stuck at low temperature): 
Stores a fault code if TFT stabilizes (stops increasing if temperature < 70 deg F, stops decreasing if temperature > 225 deg F) before reaching the temperature region where all MIL tests are enabled (70 to 225 deg F). If TFT remains constant (+/- 2 deg F) for approximately 2.5 minutes of vehicle driving outside the 70 to 225 deg F zone a P0711 fault code will be stored. Old logic used to indicate a "pass" for a single delta, and not test until the normal operating region (70-225 deg F) was reached.
Shift Solenoid Check Operation

DTCs SS A 
P0750 - open circuit
P0751 - functionally failed off
P0752 - functionally failed on
P0973 - short to ground
P0974 - shorts to power
P1714 ISIG functional (4R70 only, replaces P0751, P0752)
SS B 
P0755 - open circuit
P0756 - functionally failed off
P0757 - functionally failed on
P0976 - short to ground
P0977 - shorts to power
P1715 ISIG functional (4R70 only, replaces P0756, P0757)
SS C 
P0760 - open circuit
P0761 - functionally failed off
P0762 - functionally failed on
P0979 - short to ground
P0980 - shorts to power
SS D 
P0765 - open circuit
P0766 - functionally failed off
P0767 - functionally failed on
P0982 - short to ground
P0983 - shorts to power
SS E 
P0770 - open circuit
P0771 - functionally failed off
P0772 - functionally failed on
P0985 - short to ground
P0986 - shorts to power
Monitor execution electrical - continuous, functional - during off to on solenoid transitions
Monitor Sequence None
Sensors OK  
Monitoring Duration 0.5 to 5 seconds for electrical checks, 10 solenoid events for functional check
TYPICAL SHIFT SOLENOID ISIG FUNCTIONAL CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Transmission Fluid Temp 70 °F 225 °F
Throttle Position positive drive torque (actual TP varies)  
TYPICAL SHIFT SOLENOID MECHANICAL FUNCTIONAL CHECK ENTRY CONDITIONS

Entry Conditions (with turbine speed)  Minimum  Maximum 
Gear ratio calculated each gear  
Throttle position positive drive torque  
TYPICAL SHIFT SOLENOID MECHANICAL FUNCTIONAL CHECK ENTRY CONDITIONS

Entry Conditions (without turbine speed)  Minimum  Maximum 
Gear ratio calculated each shift  
Throttle position positive drive torque  
TYPICAL SHIFT SOLENOID MALFUNCTION THRESHOLDS

Electrical circuit check: Output driver feedback circuit does not match commanded driver state for 0.5 - 5.0 seconds
Electrical current check: Feedback current out of range for 0.5 seconds
ISIG functional check: ISIG chip hardware circuit does not detect characteristic current dip and rise produced by solenoid movement.
Mechanical functional check: Actual obtained gear or shift pattern indicates which shift solenoid is stuck on or off.
GEAR RATIO CHECK OPERATION

DTCs P0731 incorrect gear 1 ratio
P0732 incorrect gear 2 ratio
P0733 incorrect gear 3 ratio
P0734 incorrect gear 4 ratio
P0735 incorrect gear 5 ratio
P0729 incorrect gear 6 ratio
P0736 incorrect reverse ratio
Monitor Execution Continuous, in each gear
Monitor Sequence None
Sensors OK TSS, OSS, wheel speed
Monitoring Duration 12 seconds
TYPICAL FORWARD GEAR RATIO CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Gear selector position forward range,
> 8 seconds
 
Engine Torque 100 NM  
Throttle position 10%  
Not shifting > 0.5 seconds  
Engine/input Speed 550 rpm  
Output Shaft Speed 250 rpm 1350 rpm
TYPICAL NEUTRAL GEAR RATIO CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Gear selector position forward range,
> 1 seconds
 
Absolute value of Engine rpm - turbine rpm   150 rpm
Output shaft speed 250 rpm 1350 rpm
TYPICAL GEAR RATIO MALFUNCTION THRESHOLDS

Forward gear check: > 30 error in commanded ratio for > 1.8 seconds that repeats 3 times
TORQUE CONVERTER CLUTCH CHECK OPERATION

DTCs P0740 - open circuit
P0742 - short to ground
P0744 - short to power
P0741 - functionally stuck off
P2758 - functionally stuck on
P1740 - Inductive signature (4R70 only, replaces P0741 / P2758)
Monitor Execution electrical - continuous,
mechanical - during lockup
Monitor Sequence None
Sensors OK TSS, OSS
Monitoring Duration Electrical - 5 seconds, Functional - 5 lock-up events
TYPICAL TCC ISIG FUNCTIONAL CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Transmission Fluid Temp 70 °F 225 °F
Engine Torque positive drive torque  
Commanded TCC duty cycle for 0 rpm slip 60% 90%
TYPICAL TCC MECHANICAL FUNCTIONAL CHECK STUCK OFF ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Throttle Position steady  
Engine Torque positive drive torque  
Transmission Fluid Temp 70 °F 225 °F
Commanded TCC duty cycle (0 rpm slip) 60% 100%
Not Shifting    
TYPICAL TCC MALFUNCTION THRESHOLDS

Electrical circuit check: Output driver feedback circuit does not match commanded driver state for 0.5 - 5.0 seconds
Electrical current check: Feedback current out of range for 0.5 seconds
ISIG functional check: ISIG chip hardware circuit does not detect characteristic current dip and rise produced by solenoid movement.
Mechanical check, stuck off: Slip across torque converter > 100 - 200 rpm or speed ratio < 0.93
Mechanical check, stuck on: Slip across torque converter < 20 rpm with converter commanded off
Mechanical check, stuck on: engine rpm < 100 after drive engagement (engine stall)
PRESSURE CONTROL SOLENOID CHECK OPERATION

DTCs P0960 - open circuit
P0960 - short to ground
P0963 - short to power
Monitor Execution Continuous
Monitor Sequence None
Sensors OK  
Monitoring Duration Electrical: 5 seconds,
Mechanical functional: up to 30 seconds
TYPICAL PRESSURE CONTROL SOLENOID MECHANICAL FUNCTIONAL CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Gear ratio calculated each gear  
Transmission Fluid Temperature 70 °F 225 °F
Throttle Position positive drive torque  
TYPICAL PRESSURE CONTROL SOLENOID MALFUNCTION THRESHOLDS

Electrical circuit check: Output driver feedback circuit does not match commanded driver state for 0.5 - 5.0 seconds
Electrical current check: Feedback current out of range for 0.5 seconds
Mechanical functional check: Actual obtained gear pattern indicates Pressure Control solenoid fault
INDUCTIVE SIGNATURE CHIP COMMUNICATION CHECK OPERATION

DTCs P1636 ISIG chip loss of communication
Monitor Execution off-to-on solenoid transitions
Monitor Sequence None
Sensors OK  
Monitoring Duration < 100 solenoid events
TYPICAL INDUCTIVE SIGNATURE CHIP COMMUNICATION CHECK ENTRY CONDITIONS

Entry Conditions  Minimum  Maximum 
Transmission Fluid Temp 70 °F 225 °F
Solenoid commanded off duration   < 2 seconds
TYPICAL INDUCTIVE SIGNATURE COMMUNICATION CHIP MALFUNCTION THRESHOLDS

Checksum error, chip not responding