P2626 - O2 Sensor Positive Current Trim Circuit/Open (Bank 1 Sensor 1)

P2626 - O2 SENSOR POSITIVE CURRENT TRIM CIRCUIT/OPEN (BANK 1 SENSOR 1)

Description:  During deceleration fuel shut-off (DFSO) the integrity of the UO2SPCT circuit is compared using the actual oxygen sensor voltage signal and an expected oxygen sensor voltage signal. This DTC sets when the actual oxygen sensor voltage exceeds the maximum expected voltage threshold for a specified amount of time.
Possible Causes: 
  • UO2SPCT circuit open
  • Corrosion
  • Incorrect connections
Diagnostic Aids: 
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to PINPOINT TEST DZ: UNIVERSAL HEATED OXYGEN SENSOR (HO2S) .