Power Door Window Initialization
Initialization
- 1.
To initialize an existing window regulator motor, the motor must first be de-initialized. This can be accomplished by disconnecting the battery cable or window motor fuse while the window is operating. After the motor has been de-initialized, reconnect the battery cable or fuse before proceeding to the following step.
NOTE:
This step is only necessary for an existing window regulator motor. If installing a new window regulator motor, proceed to Step 2.
WARNING:
Before beginning any service procedure in this article, refer to health and safety warnings in GENERAL INFORMATION
. Failure to follow this instruction may result in serious personal injury.
- 2.
With the door window in the fully OPEN position, press and hold the window control switch in the UP position at the second detent until the window glass stalls into the glass top run for at least 2 seconds. Release the switch.
NOTE:
The door MUST be closed during this procedure (for convertibles, the top and quarter glass must be in the CLOSED and UP position) in order for the door window motor to initialize.
WARNING:
Keep objects and body parts clear of the glass panel when carrying out the initialization procedure. During the initialization procedure, the glass panel closes with high force and cannot detect objects in its path. Failure to follow this instruction may result in serious personal injury.