Contaminated Refrigerant Handling
Special Tool(s) / General Equipment
| Refrigerant Identification Equipment |
Activation
- 1.
Refer to: Health and Safety Precautions
- 2.
Use the refrigerant identification equipment to check that there is contaminated refrigerant in the air conditioning system.Use the General Equipment: Refrigerant Identification Equipment
- 3.
2. Inform the customer about the additional costs involved to repair the system because of the contamination.
- 4.
3. Use a suitable A/C service unit designed for the purpose of collecting and storing contaminated refrigerant and dispose of the contaminated refrigerant as hazardous waste. Follow the manufacturer's instructions when working with the A/C service unit.