Check Valve
- Inspect check valve whenever hose to valve is disconnected or if check valve failure is suspected.
- If air pump is inoperative and shows signs of exhaust gases entering pump, check valve failure is indicated. Air flow must be in one direction only, toward exhaust manifold. If air flow is in both directions, replace check valve.