Passlock Module Data
Passlock Module Data
| Ignition Switch in the RUN position/Vehicle in PARK | ||
|---|---|---|
| Scan Tool Parameter | Units Displayed | Typical Data Value |
| Passlock™ Data Voltage | Volts | 0.86-4.28 Volts - Typical |
| Passlock™ State | Ignition OFF/Normal Decision/Learn Passlock™/Tamper/Monitor Passlock™/Fail Enabled/Fail Enabled Dec/Seedkey Lrn Pend/Seedkey Learn/Auto Lrn Pend/Auto Learn | Monitor Passlock™ |
| Passlock™ Code | Open/Short/Tamper/Numeric | Valid Code XX |
| Security Lamp Feedback | Volts | 0.0-16.0 Volts (Varies) |
| Battery Voltage | Volts | 9.0-16.0 Volts (Varies) |
| Ignition 1 | ACTIVE/INACTIVE | ACTIVE |
| Passlock™ Power | ACTIVE/INACTIVE | ACTIVE |
| Tamper Timer | SECONDS | 0-600 Seconds |
| Auto Learn Timer | SECONDS | 0-600 Seconds |
| Security Lamp State | ON/OFF/FLASHING | OFF |