Drive Motor Generator Battery Control Module Scan Tool Information
The Drive Motor Generator Battery Control Module Scan Tool Data List contains all Hybrid Battery related parameters that are available on the scan tool. The list is arranged in alphabetical order. A given parameter may appear in any one of the data lists, and in some cases may appear more than once, or in more than one data list in order to group certain related parameters together.
Use the scan tool data values under the following conditions:
- The Diagnostic System Check - Vehicle is complete.
- The On-Board Diagnostics are functioning properly.
- There are no diagnostic trouble codes (DTCs) present.
Only the parameters listed below are referenced in this manual for diagnosis. If a scan tool displays other parameters, those values are not recommended by General Motors for use in diagnosis.
If all values are within the expected range described below, refer to Symptoms - Hybrid Energy Storage for diagnosis.
The scan tool values from a properly running vehicle may be used for comparison with the vehicle you are diagnosing. The values below represent a typical display recorded from a properly functioning system.
| Parameter | System State | Expected Value | Description |
|---|---|---|---|
| Operating Conditions: Engine at idle, upper radiator hose hot, closed throttle, transmission in Park, closed loop operation, accessories OFF, brake pedal not applied, Hood Open, State of charge 60-80 percent. | |||
| 300 V Isolation Test Conditions Met | Yes/No | No | This parameter displays the status of the high voltage (HV) system as determined by the drive motor generator control module. This parameter indicates if the isolation test will run at the next High voltage power down cycle. Should display "Yes" after the ignition is cycled to "Off" and before the isolation test runs. |
| 300 V Isolation Test Status | Not Run/In Progress/Passed/Failed | Passed or In Progress | This parameter displays the status of the "300 V Isolation Test" diagnostic after running during normal vehicle operation or after running the special functions device control located under the drive motor generator control module menu. This parameter can display Not Run, In Progress, Passed, or Failed. |
| Air Bags Deployed | Yes/No | No | This parameter displays information about contactor open reasons as determined by the drive motor generator control module. "Yes" indicates that an airbag deployment or high voltage circuit impact detection (HVCID) sensor activation has occurred. |
| Calc. Hybrid Batt. Current | amps | -2.00 to +2.00 amps | This parameter displays the hybrid battery current as determined by the drive motor generator control module. This is a discreet input to the drive motor generator control module from the current sensor located in the drive motor generator battery. The drive motor generator control module displays this current sensor parameter in Amps. This is a signed value. "+" sign represents energy being used from the hybrid battery or discharge and "-" sign represents energy being provided back to the hybrid battery or charge. |
| Calc. Hybrid Batt. Resistance | Ohms | 0.48 ohms | This parameter displays the total impedance (in ohms) of the hybrid battery, as calculated by the drive motor generator control module. The drive motor generator control module uses all 22 hybrid battery resistance measurement values in this calculation. |
| Contactor Commanded Open | Yes/No | No | This parameter displays information about the high voltage contactor commanded position as determined by the drive motor generator control module. "Yes" indicates that the drive motor generator control module is commanding the contactors to open. |
| Contactor Sys. Req. Signal | Open/Closed | Closed | This parameter displays the requested contactor state command from the hybrid powertrain control module to the drive motor generator control module over the communication circuit for the hybrid battery contactor control as determined by the drive motor generator control module. This can Display open or closed. |
| Contactor Sys. Req. CKT Command | % | 30% | This parameter displays the discrete PWM command from the hybrid powertrain control module for the hybrid battery contactor control as determined by the drive motor generator control module. |
| Contactor System Status | Open/Closed/Precharging/Precharge Failed/Precharge Inhibit | Closed | This parameter displays the status of the hybrid battery contactor system as determined by the drive motor generator control module. The status can be displayed as open, closed, precharging, precharge failed or precharge inhibit. |
| Control Module Voltage Signal | Yes/No | No | This parameter displays the state of the control module voltage supply circuit. The drive motor generator control module. "Yes" indicates that control module voltage supply is present. |
| Control Module Voltage | V | 13.7-14.5 V | This parameter displays the value of the input voltage used to power up the drive motor generator control module, as measured by the drive motor generator control module. |
| HVIC Fault | Yes/No | No | This parameter displays information about contactor open reasons as determined by the drive motor generator control module. "Yes" indicates that The high voltage interlock circuit has a fault. |
| HVIC Return Current | mA | 6.00 mA | This parameter displays the amount of return current in milli amps returning back to the drive motor generator control module for high voltage interlock circuit detection as determined by the drive motor generator control module. |
| HVIC Source Current | mA | 6.25 mA | This parameter displays the amount of current sourced in milli amps for high voltage interlock current detection circuit as determined by the drive motor generator control module. |
| Hybrid Batt. Charge Hrs. | Ahrs | Varies | This parameter displays the total accumulated amount of amp hours charged or put in to the hybrid batteries as determined by the drive motor generator control module). This information will be reset to 0 when the drive motor generator control module is reprogrammed or replaced. |
| Hybrid Batt. Charge Pwr Available | Watts | 29100 to 30000 Watts | This parameter displays the charge power available in watts from the hybrid battery as determined by the drive motor generator control module power limit calculation. |
| Hybrid Batt. Current Sensor | V | 2.4-2.6 V | This parameter displays the hybrid battery current sensor in volts as determined by the drive motor generator control module. This is a discreet input from the current sensor. |
| Hybrid Batt. Discharge Hrs. | Ahrs | Varies | This parameter displays the total accumulated amount of amp hours discharged from the hybrid batteries as determined by the drive motor generator control module. This information will be reset to 0 when the drive motor generator control module is reprogrammed or replaced. |
| Hybrid Batt. Discharge Power Available | Watts | 29100 to 30000 Watts | This parameter displays the discharge power available in watts from the hybrid battery as determined by the drive motor generator control module power limit calculations. |
| Hybrid Batt. Inlet Air Temperature Sensor | V | 3.2 V | This parameter displays the hybrid battery air inlet temperature, in volts, as measured by the drive motor generator control module. This sensor is located in the inlet side of the hybrid battery coolant cooler radiator. |
| Hybrid Batt. Max. Cell Temp. | °C (°F) | 26°C (79°F) | This parameter displays the highest temperature value of all the hybrid battery modules temperature sensors as determined by the drive motor generator control module. |
| Hybrid Batt. Min. Cell Temp. | °C (°F) | 24°C (75°F) | This parameter displays the lowest temperature value of all the hybrid battery module temperature sensors, as determined by the drive motor generator control module. |
| Hybrid Batt. Mod. 1 Temperature | °C (°F) | 24°C (75°F) | This parameter displays the temperature of Hybrid Battery Module Temperature sensor 1 as measured by the drive motor generator control module, in °C (°F). The Hybrid Battery Module Temperature sensor 1 is located internal to the hybrid battery. |
| Hybrid Batt. Mod. 1 Temp. Sensor | V | 3.2 V | This parameter displays the Hybrid Battery Module temperature sensor 1, measured in volts, as determined by the drive motor generator control module. The Hybrid Battery Module Temperature sensor 1 is located internal to the hybrid battery. |
| Hybrid Batt. Mod. 2 Temperature | °C (°F) | 26°C (79°F) | This parameter displays the temperature of Hybrid Battery Module Temperature sensor 2 as measured by the drive motor generator control module, in °C (°F). The Hybrid Battery Module Temperature sensor 2 is located internal to the hybrid battery. |
| Hybrid Batt. Mod. 2 Temp. Sensor | V | 3.2 V | This parameter displays the Hybrid Battery Module temperature sensor 2, measured in volts, as determined by the drive motor generator control module. The Hybrid Battery Module Temperature sensor 2 is located internal to the hybrid battery. |
| Hybrid Batt. Mod. 3 Temperature | °C (°F) | 25°C (77°F) | This parameter displays the temperature of Hybrid Battery Module Temperature sensor 3 as measured by the drive motor generator control module, in °C (°F). The Hybrid Battery Module Temperature sensor 3 is located internal to the hybrid battery. |
| Hybrid Batt. Mod. 3 Temp. Sensor | V | 3.2 V | This parameter displays the Hybrid Battery Module temperature sensor 3, measured in volts, as determined by the drive motor generator control module. The Hybrid Battery Module Temperature sensor 3 is located internal to the hybrid battery. |
| Hybrid Batt. Mod. 4 Temperature | °C (°F) | 26°C (79°F) | This parameter displays the temperature of Hybrid Battery Module Temperature sensor 4, measured by the drive motor generator control module, in °C (°F). The Hybrid Battery Module Temperature sensor 4 is located internal to the hybrid battery. |
| Hybrid Batt. Mod. 4 Temp. Sensor | V | 3.2 V | This parameter displays the Hybrid Battery Module temperature sensor 4, measured in volts, as determined by the drive motor generator control module. The Hybrid Battery Module Temperature sensor 4 is located internal to the hybrid battery. |
| Hybrid Batt. Pack Fan Commanded | % | 0% | This parameter displays the duty cycle of the hybrid battery fan command in percent, as determined by the drive motor generator control module. |
| Hybrid Batt. Pack Resistance | Ohms | 0.024 ohms | This parameter displays the impedance in ohms of the highest battery pair within the hybrid battery assembly, as measured by the drive motor generator control module. |
| Hybrid Battery 1 through 22 | V | 10-15 V | This parameter displays the voltage value of the individual the hybrid battery voltage measured by the drive motor generator control module. |
| Hybrid Batt. Inlet Air Temperature | °C (°F) | 23°C (73°F) | This parameter displays the air inlet temperature, in °C (°F), internal to the hybrid battery, as measured by the drive motor generator control module. This sensor is located in the inlet duct for the hybrid battery coolant cooler radiator. |
| Hybrid Battery Pack Calculated | V | 264-280 V | This parameter displays the total voltage of the hybrid battery assembly, as calculated by the drive motor generator control module by summing up all 22 hybrid battery voltage measurement values. |
| Hybrid Battery Pack Fan | RPM | 21% | This parameter displays the speed of the hybrid battery fan in RPM, as measured by the drive motor generator control module. |
| Hybrid Battery SOC | % | 70% | This parameter displays the calculated state of charge (SOC) of the hybrid battery as determined by the drive motor generator control module. This calculation incorporates many factors such as temperature, voltage and current. |
| Hybrid Battery Terminal | V | 264-280 V | This parameter displays the total hybrid battery voltage as measured by the drive motor generator control module on the vehicle side of the High Voltage contactors. This measurement is only accurate when the both of the HV contactors are closed. |
| Max. Hybrid Batt. Module Voltage | V | 15.8 V | This parameter displays the highest value in Volts of the 22 hybrid battery pair voltage measurement values, as determined by the drive motor generator control module. |
| Min. Hybrid Batt. Module Voltage | V | 15.5 V | This parameter displays the lowest value in volts of the 22 hybrid battery module voltage measurement values, as determined by the drive motor generator control module. |
| Precharge Ckt Overtemperature | Yes/No | No | This parameter displays the status of the 300 V system. "Yes" indicates this is a reason the drive motor generator control module can not close the high voltage contactors. This is not an actual temperature measurement. This is a calculation made by the drive motor generator control module. "Yes" indicates that the drive motor generator control module has calculated that the precharge circuit may be hot and has started the precharge wait time counter. |
| Precharge Inhibited | Yes/No | No | This parameter displays information about contactor open reasons as determined by the drive motor generator control module. "Yes" indicates that the drive motor generator control module is disabling the precharge function. |
| Precharge Time Too long | Yes/No | No | This parameter displays the status of the 300 V system. "Yes" indicates this is a reason the drive motor generator control module can not close the high voltage contactors. The precharge time has taken too long. HV DC cables or circuits may be shorted causing higher current draws during the precharge process. |
| Precharge Time Too Short | Yes/No | No | This parameter displays the status of the 300 V system. "Yes" indicates this is a reason the drive motor generator control module can not close the high voltage contactors. The precharge time was to fast. High voltage DC cables/circuit may be open causing a fast precharge. |
| Precharge wait time | Seconds | 0 | This parameter displays the amount of time, in seconds, until the drive motor generator control module will allow a 300 V precharge sequence to occur. The drive motor generator control module can disable precharge in order to protect the precharge resistor and circuit from overheating. |
| Service Disconnect | Yes/No | No | This parameter displays information about contactor open reasons as determined by the drive motor generator control module. "Yes" indicates that the HV manual disconnect lever has been removed. |
| Output Control | Description |
|---|---|
| Battery Pack Fan Speed |
|
| Pump Motor | The drive motor generator control module commands the coolant pump ON/OFF. |
| Negative Contactor |
|
| Positive Contactor |
|
| Precharge Contactor |
|
| 300 V Isolation Test |
|