LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> GMC >> 2002 >> Jimmy 2D Utility, Part Time, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 1963 (Vehicle Diagnostic Information (1 Of 2)) >> Specifications >> Generator Battery Disconnect Control Module Scan Tool Information
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Generator Battery Disconnect Control Module Scan Tool Information

WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Battery Energy Control Module Scan Tool Data Parameters

Parameter System State Expected Value Description
Operating Conditions:  Ignition ON
ECM Des. Contactor Position - Closed The scan tool displays Closed, Open Impact DTC, Open Service Dis, ECM Fault, Overtemp or Fault.
Calc. Hybrid Batt. Current - Varies This displays amps.
Hybrid Batt. High Current Sensor - Varies This displays Volts or amps.
Hybrid Batt. Low Current Sensor - Varies This displays Volts or amps.
Hybrid Batt. Mod. 1 Temperature - Varies This displays °C (°F).
Hybrid Batt. Mod. 2 Temperature - Varies This displays °C (°F).
Hybrid Batt. Mod. 3 Temperature - Varies This displays °C (°F).
Hybrid Batt. Mod. 4 Temperature - Varies This displays °C (°F).
Hybrid Batt. Mod. 5 Temperature - Varies This displays °C (°F).
Hybrid Batt. Mod. 6 Temperature - Varies This displays °C (°F).
Hybrid Batt. Mod. 1 Temperature Sensor - Varies This displays Volts.
Hybrid Batt. Mod. 2 Temperature Sensor - Varies This displays Volts.
Hybrid Batt. Mod. 3 Temperature Sensor - Varies This displays Volts.
Hybrid Batt. Mod. 4 Temperature Sensor - Varies This displays Volts.
Hybrid Batt. Mod. 5 Temperature Sensor - Varies This displays Volts.
Hybrid Batt. Mod. 6 Temperature Sensor - Varies This displays Volts.
Hybrid Battery 1 - Varies This displays Volts.
Hybrid Battery 2 - Varies This displays Volts.
Hybrid Battery 3 - Varies This displays Volts.
Hybrid Battery Current - Varies This displays Zero Range, DC/AC Polarity or High/Low Sensor.
Hybrid Battery Pack Fan - Varies This displays RPM.
Hybrid System Voltage - Varies This displays Volts.
Hybrid System Voltage - Varies This displays Volts.
SGCM 12 Volt Converter - Varies This displays amps.
Battery Energy Control Module Scan Tool Output Controls

Output Control Description
Battery Pack Fan Speed This output control commands the battery pack fan ON and OFF.