| Case 1 |
Main Action |
- Level 2 process monitoring
|
- Contact resistance in connectors
- Faulty ECM
|
| Prerequisite condition |
- Ignition switch is turned "ON" or engine is running.
|
| Threshold Value |
- Engine speed under ETC limp home activation is higher than 1760 rpm.
- Difference between actual and targeted torque is higher than 22 to 400Nm. (torque monitoring error)
|
| Diagnosis Time |
|
| Case 2 |
Main Action |
- Check RAM area and communication connections
|
| Prerequisite condition |
- Ignition switch is turned "ON".
|
| Threshold Value |
- RAM test/checksum/SPI communication failure
|
| Diagnosis Time |
|
| Case 3 |
Main Action |
- Level 3 process monitoring
|
| Prerequisite condition |
- Ignition switch is turned "ON".
|
| Threshold Value |
- RAM/ROM error on microcontroller.
- Process monitoring test calculation failed
|
| Diagnosis Time |
|
| MIL On Condition |
|