Throttle Position Sensor (Metro A/T)
Disconnect TPS electrical connection. Install proper thickness feeler gauge between stop screw and lever. Using ohmmeter, check continuity or resistance between designated terminals. See Fig 1
for terminal identification. Adjust or replace TPS if not within specification. See THROTTLE POSITION SENSOR (TPS) RESISTANCE
.
THROTTLE POSITION SENSOR (TPS) RESISTANCE (METRO (A/T)
| Application & Condition |
Ohms |
| Between Terminals A & B |
Continuity Between |
| Between Terminals A & B |
No Continuity |
| Between Terminals A & B |
Continuity |
| Between Terminals A & D |
4370-8130 |
| Between Terminals A & C |
240-1140 |
| Between Terminals A & C |
3170-6600 |
Courtesy of GENERAL MOTORS CORP.