Vacuum Pump Check
Connect hand-held vacuum pump to ACT side of vacuum pump. Connect a jumper wire between positive battery terminal and vacuum pump terminal No. 1. See Figure -32. Connect another jumper wire between negative battery terminal and vacuum pump terminal No. 2. Approximately 7.8 in. Hg vacuum should be present at vacuum pump. If vacuum is not as specified, replace vacuum pump.