Power Steering Pressure Switch
ECM applies and monitors reference voltage to power steering pressure switch from ECM terminal A6 (TBI) or ECM terminal A19 on (MFI). ECM applies and monitors reference voltage to power steering pressure switch. On all models, when steering wheel is turned, pressure switch closes, pulling reference voltage low. ECM uses this signal to help determine control of idle speed control system.