Vacuum Switch E
- Disconnect vacuum hose to vacuum switch E and connect a hand vacuum pump to hose. Apply vacuum to switch. Check for voltage at Brown/Black wire (1500 HF Calif.) of vacuum switch E.
- Voltage should be available when vacuum below 2.2 in. Hg (1500 HF Calif.) is applied. If there is no voltage, replace vacuum switch A and retest.