Air Control Valve B
- Disconnect upper vacuum hose No. 32 from air control valve B. Connect vacuum pump to hose. Connect vacuum pump to lower hose of air control valve. See Fig 1 . Apply vacuum to lower hose. It should hold vacuum.
- Apply vacuum to air control valve upper vacuum hose. With vacuum applied at upper hose, lower hose should release vacuum. If valve fails either check, replace valve.