EVAP Canister Replacement
- Remove the EVAP canister cover (A).
- Remove the hoses (A), the FTP sensor 3P connector (B), and the EVAP canister vent shut valve 2P connector (C).
- Remove the bolts (D).
- Remove the EVAP canister (E).
- Remove the EVAP canister bracket (A).
- Install the canister in the reverse order of removal.