Item Measurement Qualification Standard or New Service Limit
Refrigerant Type   HFC-134a (R-134a)
Capacity of system   450-500 g (15.8-17.6 02) -
Refrigerant oil Type   SP-10 (P/N38897-P13-A01AH)
Capacity of components Condenser (including dryer desiccant) 25 mL (5/6 fl.oz)
Evaporator 35mL (1 1/6 fl.oz)
Each line and hose 10 mL (1/3 fl.oz)
Dryer desiccant 10 mL (1/3 fl.oz)
Compressor 80-90 mL (2 2/3-3 fl.oz)
Compressor Field coil resistance At 68°F (20°C) 3.35-3.65 Ω
Pulley-to-armature plate clearance   0.35-0.65 mm (0.014-0.025 in) -