| 1 |
BRN/YEL (LG3) |
In all ignition switch positions |
Measure the voltage to ground: There should be battery voltage. |
- Faulty PCM
- An open or high resistance in the wire
|
| 5 |
WHT/RED (+B) |
Under all conditions |
Measure the voltage to ground: There should be battery voltage. |
- Blown No. 7 (7.5 A) fuse in the under-dash fuse/relay box
- An open or high resistance in the wire
|
| 3 |
BLK/GRN (IG1) |
Ignition switch ON (II). |
Measure the voltage to ground: There should be battery voltage. |
- Blown No. 19 (15 A) fuse in the under-dash fuse/relay box
- An open or high resistance in the wire
|
| 2 |
RED/BLU (IMOCD) (S-NET) |
Under all conditions
NOTE:
Test with imoes unit, PCM, and immobilizer control unit-receiver disconnected.
|
Check for continuity to ground: There should be no continuity. |
- Faulty immobilizer control unit-receiver
- Faulty PCM
- An open or high resistance in the wire
|
Check for continuity between terminal No. 2, PCM connector A (49P) terminal No. 46, and immobilizer control unit-receiver terminal No. 2: There should be continuity |
| 4 |
RED/WHT (KEY SW) |
Ignition key removed from the ignition switch |
Measure the voltage to ground: There should be battery voltage |
- Faulty PCM
- Faulty ignition key switch
- A short to ground in the wire
|
| Ignition key inserted in the ignition switch |
Measure the voltage to ground: There should be less than 0.2 V. |
- Faulty ignition key switch
- An open or high resistance in the wire
- Poor ground (G401) or an open in the ground wire
|