Refrigerant Leak Check: Notes
Special Tools Required
- Leak Detector YGK-H-10PM*
- Leak Detector HLD-100*
- Leak Detector TIFZX-1*
- OPTIMAX Jr. A/C Leak Detection Kit TRP124893*
*These tools are available through the Honda Tool and Equipment Program; call 888-424-6857
CAUTION:
- Air conditioning refrigerant or lubricant vapor can
- irritate your eyes, nose, or throat.
- Be careful when connecting service equipment.
- Do not breathe refrigerant or vapor.
- Do not operate the leak detector near flammable vapors. Its sensor operates at high temperatures, and could ignite the vapors, resulting in personal injury and/or damage to the equipment.
- IMA components are located near A/C system components. Make sure you have read the IMA service precautions before doing repairs or service.
NOTE:
- If accidental system discharge occurs, ventilate the work area before resuming service.
- Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.
- Check the system for leaks using an R-134a refrigerant leak detector with an accuracy of 14 g (0.5 oz) per year or better