Calibration Completion Check
Check if calibration is completed by doing the following:
- Stop the vehicle and shift into neutral (M/T) or P or N (A/T, CVT) position.
- Turn the ignition switch to LOCK (0), or press the engine start/stop button to select the OFF mode.
- Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode and wait to see the low pressure indicator come on for 2 seconds and then off.
- Do not drive the vehicle and wait for 45 seconds as is.
- If the calibration is completed, the indicator does not come on. If the calibration is not yet completed, then the indicator will come on for 2 seconds and then go off.
NOTE:
The calibration check process will be interrupted if the vehicle moves. Do the troubleshooting if the indicator does not go off after 2 seconds, keeps blinking or stays on when the vehicle is in the ON mode.