Battery module output control
The battery module output control maintains the battery module SOC and temperature. It also prolongs battery life by setting the correct limits for battery output to the IMA motor and battery input from charging. Without this control, the battery module would quickly deteriorate.
HDS PARAMETER WITH NORMAL CONTROL AREA
| HDS Parameter | Normal Control Area |
|---|---|
| SOC | 25 - 75 % |
| SOC POWER SAVE (PSSOC) | ON/OFF |
HDS PARAMETER WITH NORMAL CONTROL AREA
| HDS Parameter | Normal Control Area |
|---|---|
| BATTERY MODULE TEMPERATURE SENSOR 1 (TBATT1) | Depend on outside air temperature |
| BATTERY MODULE TEMPERATURE SENSOR 2 (TBATT2) | Depend on outside air temperature |
| BATTERY MODULE TEMPERATURE SENSOR 3 (TBATT3) | Depend on outside air temperature |
| BATTERY MODULE TEMPERATURE POWER SAVE (PSTBATT) | ON/OFF |
Consecutive output control
To prevent battery module overheating and deterioration, the battery module output control manages the consecutive outputs of battery assist and sets an allowable amount.