Possible Cause
NOTE:
The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
- Bypass contactor PRE line open
- High voltage sub contactor CNTN line open
- High voltage contactor/High voltage sub contactor/Bypass contactor CNTPSIN line open
- High voltage contactor CNTP line open
- High voltage contactor CNTP line short
- High voltage contactor CNTPSIN line short
- Battery power cable open
- Bus bar poor connection
- Bus bar failure
- Junction board poor connection
- Main fuse failure
- Main switch poor connection
- Main switch failure
- Bypass resistor poor connection
- Bypass resistor failure
- Bypass contactor stuck off
- High voltage sub contactor stuck off
- High voltage contactor stuck off
- MPI module internal circuit failure
- Failure of the vehicle by the collision
- SRS unit internal circuit failure
- Battery module internal circuit failure
- Electric A/C compressor internal circuit failure
- DC-DC converter internal circuit failure
- Battery condition monitor module internal circuit failure
- PCU internal failure