LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2021 >> Insight Touring >> Repair and Diagnosis >> Body & Frame >> Windows >> Windows / Glass - Testing & Troubleshooting >> Learning Reset Clear >> Resetting the Power Window Control Unit >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Resetting the Power Window Control Unit: Procedure

Reset the power window control unit after doing any of the following actions:

NOTE: 

Without HDS 

  1. Power Window Control Unit - Reset

    NOTE:  Close the door, and leave it closed until the procedure is complete.

    1. Turn the vehicle to the ON mode.

    2. Move the power window all the way down with the power window DOWN switch.

    NOTE:  Steps 3-6 must be done within 5 seconds of each other.

    3. Turn the vehicle to the OFF (LOCK) mode.

    GHH388945Courtesy of HONDA, U.S.A., INC.

    4. Press and hold the power window DOWN switch.

    5. Turn the vehicle to the ON mode.

    6. Release the power window DOWN switch.

    7. Repeat step 3-6 three more times.

    8. Confirm that AUTO UP and AUTO DOWN do not work. If AUTO UP and DOWN work, go back to step 2.

    9. Move the power window all the way down with the power window DOWN switch of the seat to be reset.

    10. Pull up and hold the power window UP switch of the seat to be reset until the window reaches the fully closed position, then continue to hold the switch for at least 1 second.

    11. Confirm that the power window control unit is reset by using the power window AUTO UP and AUTO DOWN functions:

    With HDS 

  2. Power Window Control Unit - Reset
    1. Connect the HDS to the data link connector (DLC)

    2. Turn the vehicle to the ON mode.

    3. Select the following menu buttons on the HDS screen in sequence.

    • Body Electrical (System Selection Menu)
    • Power Window
    • Adjustment
    • Power Window Reset for Driver Side(Select the menu button corresponding to the switch to be reset)

    4. Confirm that the power window control unit is reset by using the power window AUTO UP and AUTO DOWN function.