Installation Procedure
- Install the generator.
- Install the generator bolts.
Tighten: Tighten the generator bolts to 50 N.m (37 lb ft).
- Install the generator cable to the generator, perform the following:
- Install the generator cable.
- Install the generator cable nut to the terminal stud.
Tighten: Tighten the generator cable nut to 9 N.m (80 lb in).
- Slide the boot over the terminal stud.
- Connect the generator electrical connector (3).
- Install the engine sight shield. Refer to Engine Sight Shield Replacement 6.0L (LQ4) in Engine Mechanical - 6.0L (LQ4).
- Install the accessory drive belt. Refer to Drive Belt Replacement - Accessory in Engine Mechanical - 6.0L (LQ4).
- Connect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure (Single Battery) .
NOTE:
Refer to Fastener Notice
in Cautions and Notices.
Fig 3: Identifying Purge Solenoid Electrical Connector, Wiring Harness Nut & Generator Electrical Connector