Typical Scan Tool Data
TP Sensor 1 and 2
| Circuit | Normal Range | Short to Ground | Open or High Resistance | Short to Voltage |
|---|---|---|---|---|
| TP Sensor 1 Signal | 0.27-4.67 V | 0 V | 0 V | 5 V |
| TP Sensor 1 5-Volt Reference | 0.27-4.67 V | 0 V | 0 V | 5 V |
| TP Sensor 1 Low Reference | 0.27-4.67 V | - | 5 V | - |
| TP Sensor 2 Signal | 0.31-4.7 V | 0 V | 5 V | 5 V |
| TP Sensor 2 5-Volt Reference | 0.31-4.7 V | 0 V | 0 V | 5 V |
| TP Sensor 2 Low Reference | 0.31-4.7 V | - | 5 V | - |