Circuit/System Testing
- Ignition ON, verify the scan tool Memory Recall Switches parameter is approximately 2.74 volts while pressing the memory 1 switch.
- If not the specified value, refer to the Memory Switch component test below. If the switch tests normal, replace the driver door switch.
- Verify the scan tool Memory Recall Switches parameter is approximately 1.78 volts while pressing the memory 2 switch.
- If not the specified value, replace the memory/heated seat switch.
- Verify the scan tool Memory Recall Switches parameter is approximately 0.96 volts while pressing the EXIT switch.
- If not the specified value, replace the memory/heated seat switch.
- If all circuits test normal, replace the MSM.